Ecosyste.ms: Issues
An open API service for providing issue and pull request metadata for open source projects.
GitHub / pyhys/minimalmodbus issues and pull requests
#133 - How to get the specific error message
Issue -
State: open - Opened by RobinGalipeau about 2 months ago
- 1 comment
#132 - serial close doesn't close because its reference dictionary remains
Issue -
State: closed - Opened by schaefer01 7 months ago
- 7 comments
#129 - If I want to read different device addresses in the same serial port, can I do it?
Issue -
State: closed - Opened by childeyouyu 9 months ago
- 2 comments
#128 - Parity configuration in documentation is wrong
Issue -
State: open - Opened by HWHardsoft 9 months ago
- 1 comment
#127 - If you read the data multiple times, you won't be able to read the data
Issue -
State: closed - Opened by childeyouyu 10 months ago
- 8 comments
#126 - Question? How to get real registers value if register data type is LINT32
Issue -
State: closed - Opened by abhishek73magar 10 months ago
- 1 comment
#125 - Wrong LRC calculation in ASCII MODE
Issue -
State: open - Opened by uaranguren 11 months ago
#124 - Possible bug in ._num_to_two_bytes function
Issue -
State: closed - Opened by cornebester about 1 year ago
- 1 comment
#123 - Consider conforming to PEP 561 in order to make type annotations usable
Issue -
State: open - Opened by alehed about 1 year ago
#122 - Timeout after frame
Issue -
State: open - Opened by pfrl about 1 year ago
#121 - Properly closing port
Issue -
State: open - Opened by ARK3r about 1 year ago
#120 - Report roundtrip time in ms
Pull Request -
State: open - Opened by wriswith over 1 year ago
#119 - Set version number to 2.1.1
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#118 - Update documentation dependencies
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#117 - Add a requirements file for docs
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#116 - Specify dependencies in readthedocs.yaml
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#115 - Add a readthedocs.yaml file
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#114 - Version 2.1.0
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#113 - Set version number to 2.1.0
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#112 - Improve documentation on release process
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#111 - Adjust timeout for DTB4824
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#110 - Document how to build in Yocto
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#109 - Improve documentation
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#108 - Add longlong (64 bit) integers
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#107 - Change internal representation to bytes
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#106 - Allow an external serial port object to instrument constructor
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#105 - Improve scripts for tests on the Delta DTB4824 instrument
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#104 - Allow integer value in write_float()
Pull Request -
State: closed - Opened by pyhys over 1 year ago
#103 - Improve documentation
Pull Request -
State: closed - Opened by pyhys over 1 year ago
- 1 comment
#102 - Checksum error in rtu mode
Issue -
State: open - Opened by MGGEL over 1 year ago
- 15 comments
Labels: Usage
#101 - Modbus ID change - Wrong return slave address
Issue -
State: open - Opened by somakelemen over 1 year ago
- 1 comment
Labels: Usage
#100 - Silent period not working for multiple devices
Issue -
State: open - Opened by thalesmaoa over 1 year ago
- 2 comments
#99 - Using CRC to correct error
Issue -
State: closed - Opened by MauroDiamantino over 1 year ago
- 2 comments
#98 - Why the silence_time can affect the roudtrip_time?
Issue -
State: open - Opened by billyhuangyr over 1 year ago
- 3 comments
#97 - extend modbus with 'readfloats' and 'readlongs'
Issue -
State: open - Opened by FLMuller over 1 year ago
Labels: enhancement
#96 - No answer
Issue -
State: closed - Opened by Grandpa-G almost 2 years ago
- 3 comments
#95 - broadcast expects answer?
Issue -
State: closed - Opened by r0oland almost 2 years ago
- 2 comments
#94 - Feature/readlonglong
Pull Request -
State: closed - Opened by martijndegouw almost 2 years ago
- 2 comments
Labels: enhancement
#93 - Why cannot you use hex numbers as registers?
Issue -
State: closed - Opened by bmoneke almost 2 years ago
- 2 comments
#92 - Instantiate instrument with serial object as parameter?
Issue -
State: closed - Opened by bmoneke almost 2 years ago
- 5 comments
Labels: enhancement
#91 - InvalidResponseError: Wrong functioncode
Issue -
State: closed - Opened by ollie-campbell almost 2 years ago
- 6 comments
#90 - Particle Counter - Cubic OPC-6510 - "write_bit" function with the value "1"
Issue -
State: closed - Opened by BAParticleCounter almost 2 years ago
- 7 comments
#89 - Sniff on SCADA systems...
Issue -
State: closed - Opened by Carmzy about 2 years ago
- 4 comments
#88 - Wrong functioncode: 3 instead of 16
Issue -
State: closed - Opened by AnonBit about 2 years ago
- 6 comments
#87 - How to check whether minimalmodbus finished his actions?
Issue -
State: closed - Opened by kang2k10 over 2 years ago
- 5 comments
#86 - How to send a non-standard function code
Issue -
State: open - Opened by larrybarello over 2 years ago
- 2 comments
Labels: Usage
#85 - Custom FPGA Modbus RTU no working on RPi, works on Windows
Issue -
State: closed - Opened by KingMorphix over 2 years ago
- 2 comments
#84 - minimalmodbus._unpack, why value = struct.unpack(formatstring, packed_bytes)[0] ?
Issue -
State: closed - Opened by patfrench almost 3 years ago
- 4 comments
#83 - how to separate the debug mode information and the result ?
Issue -
State: closed - Opened by patfrench almost 3 years ago
- 4 comments
#82 - Compatibility with non-standard Elektro Automatik equipment
Pull Request -
State: open - Opened by SengerM almost 3 years ago
Labels: enhancement
#81 - [isar] Build minimalmodbus
Issue -
State: closed - Opened by MickaelDelanoe almost 3 years ago
- 9 comments
#80 - how to make a retry (in case of no communication) ?
Issue -
State: closed - Opened by patfrench almost 3 years ago
- 2 comments
#79 - minimalmodbus Yocto recipe fails
Issue -
State: closed - Opened by lemmi25 almost 3 years ago
- 10 comments
#78 - Function code 16 not accepting integers for `Float` payload anymore
Issue -
State: closed - Opened by alihamdan almost 3 years ago
- 1 comment
Labels: bug
#77 - For custom function codes via the `_perform_command()` function, is there a way to force how many payload bytes are returned?
Issue -
State: closed - Opened by emptor8 about 3 years ago
- 2 comments
#76 - How to add caracter NULL in minimalmodbus.write_string() ?
Issue -
State: closed - Opened by patfrench about 3 years ago
- 7 comments
#75 - Modbus RTU minimalmodbus.InvalidResponseError
Issue -
State: closed - Opened by Bogaerts-Gaetan about 3 years ago
- 4 comments
#74 - Feature request: use bytes instead of str
Issue -
State: closed - Opened by j123b567 about 3 years ago
- 3 comments
Labels: enhancement
#73 - Are the BYTEORDER_*_SWAP constants the wrong way round?
Issue -
State: closed - Opened by acetylen about 3 years ago
- 4 comments
#72 - Modbus TCP implementation
Issue -
State: open - Opened by ihategoto over 3 years ago
- 1 comment
Labels: enhancement
#71 - Minimalmodbus don't write values above 1000
Issue -
State: closed - Opened by aldosola over 3 years ago
- 2 comments
Labels: Usage
#70 - Add before_transfer callback
Pull Request -
State: closed - Opened by zyura over 3 years ago
- 3 comments
#69 - FD leak for serial port
Issue -
State: open - Opened by anatoly-savchenkov over 3 years ago
- 5 comments
Labels: bug
#68 - long sleep times when changing system clock
Issue -
State: closed - Opened by vthielen over 3 years ago
- 2 comments
#67 - Long wait time between receiving a reply and sending the next request
Issue -
State: open - Opened by JoeEarlam over 3 years ago
- 7 comments
#66 - Can minimalmodbus read unsigned char type result?
Issue -
State: closed - Opened by song85129 over 3 years ago
- 2 comments
#65 - help needed read register low high byte
Issue -
State: closed - Opened by riker65 over 3 years ago
- 6 comments
Labels: Usage
#64 - Too short start of frame
Issue -
State: closed - Opened by DaveCalaway over 3 years ago
- 1 comment
#63 - How to measure round trip time
Issue -
State: closed - Opened by tr-gis almost 4 years ago
- 4 comments
Labels: enhancement
#62 - Checksum error
Issue -
State: closed - Opened by GerfriedC almost 4 years ago
- 2 comments
#61 - Response leading 0x00 thrown crc error
Issue -
State: closed - Opened by buffedelic almost 4 years ago
- 1 comment
#60 - Doc: BYTEORDER_BIG_SWAP is "PDP endian"
Pull Request -
State: closed - Opened by edgar-bonet almost 4 years ago
- 2 comments
#59 - Simple modbus write to register example
Issue -
State: closed - Opened by krupis about 4 years ago
- 2 comments
#58 - Issue with large register addresses
Issue -
State: closed - Opened by tr-gis about 4 years ago
- 3 comments
#57 - No response error from Instrument after several successful readings in Modbus-RTU mode
Issue -
State: closed - Opened by amandeep16 about 4 years ago
- 7 comments
#56 - Would it be possible to handle Modbus TCP ?
Issue -
State: closed - Opened by Pyponou over 4 years ago
#55 - Communication work with v0.7 but not with v1.0.2
Issue -
State: closed - Opened by viewpointsa over 4 years ago
- 4 comments
Labels: bug
#54 - cannot change serial.parity
Issue -
State: closed - Opened by rma-ln over 4 years ago
- 2 comments
#53 - Cannot change baud rate when extending
Issue -
State: closed - Opened by Boo1098 over 4 years ago
- 1 comment
#52 - Using special function codes
Issue -
State: closed - Opened by luixal over 4 years ago
- 2 comments
#51 - Changing byte order in CRC checksum
Issue -
State: closed - Opened by maxelot over 4 years ago
- 2 comments
#50 - Add support for broadcast address 0
Pull Request -
State: closed - Opened by j123b567 over 4 years ago
- 2 comments
Labels: enhancement
#49 - How can I change the slave address?
Issue -
State: closed - Opened by johnjairo04 over 4 years ago
- 2 comments
Labels: Usage
#48 - Why method _onebyte_string_to_num() doesn't exist?
Issue -
State: closed - Opened by fsodano1 over 4 years ago
- 1 comment
#47 - Convert read_registers to long
Issue -
State: closed - Opened by orcunbaslak over 4 years ago
- 1 comment
#46 - 'minimalmodbus' has no attribute 'instrument'
Issue -
State: closed - Opened by joshuacox over 4 years ago
- 3 comments
Labels: Usage
#45 - Issue in subsequent read of 2 registers
Issue -
State: closed - Opened by amitrana3348 almost 5 years ago
- 2 comments
#44 - Package dummy_serial.py again
Issue -
State: closed - Opened by geowiwi almost 5 years ago
- 1 comment
Labels: enhancement
#43 - Handling of broadcast - no response expected
Issue -
State: closed - Opened by j123b567 almost 5 years ago
- 1 comment
Labels: enhancement
#42 - teste implementação usando gpio
Pull Request -
State: closed - Opened by jefersondeff about 5 years ago
- 1 comment
#41 - Read bit seems to read two bits
Issue -
State: closed - Opened by haiyuehan over 5 years ago
- 2 comments
#40 - Read and write flag registers
Issue -
State: closed - Opened by cristianlivella over 5 years ago
- 1 comment
#39 - How to read Error Message
Issue -
State: closed - Opened by hknblt over 5 years ago
- 1 comment
#38 - write_long() using function code 6
Issue -
State: closed - Opened by veeraragav over 5 years ago
- 2 comments
#37 - "ValueError: Wrong functioncode: 4 instead of 3. The response is: '\x01\x04\x04\x00\x00\x00\x00û\x84'"
Issue -
State: closed - Opened by laneschmidt about 6 years ago
- 1 comment
#36 - write_register pauses indefinitely when no slave is connected
Issue -
State: closed - Opened by austinstover about 6 years ago
- 2 comments
Labels: bug
#35 - Read Multiple coils?
Issue -
State: closed - Opened by Devangsavla about 6 years ago
- 1 comment
#34 - I want to know how much delay can be achieved in continuous reading and writing.
Issue -
State: closed - Opened by leytonxu about 6 years ago
- 2 comments
#33 - Added option: Clear buffers before each transaction
Pull Request -
State: closed - Opened by mrrs6 about 6 years ago
- 2 comments
Labels: enhancement
#32 - ModBus on Linux Aria Board fails
Issue -
State: closed - Opened by Domi1993 about 6 years ago
- 5 comments