#39 - Connect to serial port?

Issue - State: closed - Opened by ryangriggs 9 days ago - 1 comment

#38 - Enumerate device tags/registers?

Issue - State: open - Opened by ryangriggs 9 days ago - 1 comment

#37 - Try to read PD10:0.KC don't work

Issue - State: open - Opened by serafimdasaudade 2 months ago

#36 - Serial port connectivity?

Issue - State: closed - Opened by ryangriggs 3 months ago - 2 comments

#35 - Read two devices at same time

Issue - State: open - Opened by agrapps 10 months ago - 1 comment

#34 - Bad Values ControlLogix Slot 8

Issue - State: closed - Opened by AlexCastro-Prog over 2 years ago - 3 comments

#33 - WIP: Implements reading ability for PLC-5

Pull Request - State: open - Opened by gfcittolin over 4 years ago - 1 comment

#32 - Allen Bradley Micrologix 1400 PLC Error "Failure (Bad values)"

Issue - State: open - Opened by youngkzy almost 5 years ago - 5 comments

#31 - Fixed a bug in the function prepareReadPacket

Pull Request - State: closed - Opened by Lucasrsv1 over 5 years ago - 1 comment

#30 - Fix ghost writings

Pull Request - State: closed - Opened by Lucasrsv1 over 5 years ago - 1 comment

#29 - Can not read string array

Issue - State: closed - Opened by srebling over 5 years ago - 6 comments

#28 - 0.1.10 crash

Issue - State: closed - Opened by srebling over 5 years ago - 1 comment

#27 - Error Bad values

Issue - State: closed - Opened by nilesh23soni over 5 years ago - 11 comments

#26 - writeItems callback always receives false

Issue - State: closed - Opened by srebling over 5 years ago - 3 comments

#25 - Looks like nodepccc is sending multiple read request

Issue - State: closed - Opened by adhavann over 5 years ago - 3 comments

#24 - Communication timeout causing node red crashes

Issue - State: closed - Opened by mariusss21 about 6 years ago - 1 comment

#23 - Fix #15: destroy the socket when cleaning up the connection

Pull Request - State: closed - Opened by gfcittolin almost 7 years ago

#22 - Fix #21: Remove dependency of underscore library

Pull Request - State: closed - Opened by gfcittolin almost 7 years ago

#21 - Remove dependency of underscore library

Issue - State: closed - Opened by gfcittolin almost 7 years ago

#20 - Fix #19: Add options to constructor to control log messages

Pull Request - State: closed - Opened by gfcittolin almost 7 years ago

#19 - Add options to constructor to control log messages

Issue - State: closed - Opened by gfcittolin almost 7 years ago - 1 comment

#18 - Can't Communicate

Issue - State: closed - Opened by dedhdude about 7 years ago - 2 comments

#17 - Basics

Issue - State: closed - Opened by QuinDennis over 7 years ago - 3 comments

#16 - Inconsistency of how optional routing header should be formed

Issue - State: closed - Opened by dom-white over 7 years ago - 3 comments

#15 - ECONNRESET error occurs when i want to connect to plc periodically

Issue - State: closed - Opened by volsoft over 7 years ago - 1 comment

#14 - ControlLogix 5000 L62

Issue - State: closed - Opened by aguilared over 7 years ago - 2 comments

#13 - dropConnection improvements

Pull Request - State: closed - Opened by dom-white almost 8 years ago

#12 - String support

Issue - State: closed - Opened by srebling almost 8 years ago - 3 comments

#11 - [Question!] Show 16 bits integer in an array (micrologix 1400)

Issue - State: closed - Opened by Jotan almost 8 years ago - 5 comments

#10 - [BUG] Overflow(?) with lost connection

Issue - State: closed - Opened by meron1122 about 8 years ago - 2 comments

#9 - [Question]Write variable, not array

Issue - State: closed - Opened by meron1122 about 8 years ago - 4 comments

#8 - CompactLogicx issue when write array

Issue - State: closed - Opened by meron1122 about 8 years ago - 2 comments

#7 - fix wrong behaviour with odd bytelength strings while reading from plc.

Pull Request - State: closed - Opened by jledun over 8 years ago - 1 comment

#6 - Remote connection

Issue - State: closed - Opened by srebling over 8 years ago - 2 comments

#5 - Do you use real in real application

Issue - State: closed - Opened by joaomello-zz almost 9 years ago - 7 comments

#4 - Timer and Counter PRE/ACC Values

Issue - State: closed - Opened by pcainc almost 9 years ago - 3 comments

#3 - Is it possible to open this up to reading tag based addresses?

Issue - State: closed - Opened by dlbrown06 over 9 years ago - 2 comments

#1 - Mapping Values to PLC5/SLC Messages for CLX

Issue - State: closed - Opened by dlbrown06 over 9 years ago - 2 comments