#632 - numpy v1.24 bug
Issue -
State: closed - Opened by Dead-Hand over 1 year ago
- 1 comment
Labels: bug, compile
#631 - Illegal instruction (core dumped) when running `rosrun kalibr kalibr_calibrate_cameras`
Issue -
State: closed - Opened by cod3monk3y over 1 year ago
- 3 comments
Labels: compile
#628 - [ERROR] [1688457338.359981]: [TargetViewTable]: Tried to add second view to a given cameraId & timestamp. Maybe try to reduce the approximate syncing tolerance..
Issue -
State: closed - Opened by SunilSrivatsav9 over 1 year ago
- 1 comment
Labels: user-platform
#626 - Question about the Detection failed.
Issue -
State: closed - Opened by hanseongbugi over 1 year ago
- 5 comments
Labels: user-platform
#626 - Question about the Detection failed.
Issue -
State: closed - Opened by hanseongbugi over 1 year ago
- 5 comments
Labels: user-platform
#623 - Optimization failed!
Issue -
State: closed - Opened by XinZhanhua over 1 year ago
- 6 comments
Labels: user-platform
#614 - Found EOF error after run kalibr_calibrate_cameras
Issue -
State: closed - Opened by jiratto over 1 year ago
- 6 comments
Labels: compile
#601 - c++17 standard compiling "error: ISO C++17 does not allow dynamic exception specifications"
Issue -
State: closed - Opened by TioeAre over 1 year ago
- 2 comments
Labels: compile
#601 - c++17 standard compiling "error: ISO C++17 does not allow dynamic exception specifications"
Issue -
State: closed - Opened by TioeAre over 1 year ago
- 2 comments
Labels: compile
#599 - Translation error (near to 0) between IMU and camera.
Issue -
State: closed - Opened by LarryDong over 1 year ago
- 6 comments
Labels: user-platform
#597 - Add support for float numpy>=1.24
Pull Request -
State: closed - Opened by jaku-jaku almost 2 years ago
- 10 comments
#597 - Add support for float numpy>=1.24
Pull Request -
State: closed - Opened by jaku-jaku almost 2 years ago
- 10 comments
#586 - difference Kalibr with classic ROS wiki mono camera calibration
Issue -
State: closed - Opened by zoldaten almost 2 years ago
- 3 comments
Labels: question
#586 - difference Kalibr with classic ROS wiki mono camera calibration
Issue -
State: closed - Opened by zoldaten almost 2 years ago
- 3 comments
Labels: question
#579 - checkerboard 8×6 NameError: global name 'errList' is not defined
Issue -
State: closed - Opened by heisetiantang about 2 years ago
- 5 comments
Labels: debugging
#572 - Wrong estimated translation IMU-Camera
Issue -
State: open - Opened by ClementLeBihan about 2 years ago
- 5 comments
Labels: user-platform
#566 - ARM compile: Could NOT find Boost (missing: python38) (found version "1.67.0")
Issue -
State: open - Opened by zoldaten about 2 years ago
- 8 comments
Labels: enhancement, compile
#549 - kalibr_calibrate_cameras command not found
Issue -
State: closed - Opened by zhonghonglong over 2 years ago
- 7 comments
Labels: compile
#532 - run " rosrun kalibr kalibr_calibrate_imu_camera " error ! How to solve?
Issue -
State: closed - Opened by fengyikawhi over 2 years ago
- 3 comments
Labels: user-platform
#480 - IR camera calibration error:No corners could be extracted
Issue -
State: closed - Opened by lanzipoi about 3 years ago
- 2 comments
Labels: user-platform
#475 - The optimize has problem
Issue -
State: closed - Opened by chongjeelee about 3 years ago
- 4 comments
#475 - The optimize has problem
Issue -
State: closed - Opened by chongjeelee about 3 years ago
- 4 comments
#451 - Some questions about calibration result
Issue -
State: closed - Opened by hankhsueh over 3 years ago
- 7 comments
Labels: question
#442 - _tkinter.TclError: couldn't connect to display
Issue -
State: closed - Opened by harezhh over 3 years ago
- 1 comment
Labels: compile
#401 - realsense d435i - OverflowError: bad numeric conversion: positive overflow
Issue -
State: closed - Opened by TouchDeeper almost 4 years ago
- 4 comments
Labels: user-platform
#401 - realsense d435i - OverflowError: bad numeric conversion: positive overflow
Issue -
State: closed - Opened by TouchDeeper almost 4 years ago
- 4 comments
Labels: user-platform
#383 - The mathematical detail in BSpline::curveQuadraticIntegralDiag()
Issue -
State: open - Opened by chengfzy about 4 years ago
- 1 comment
Labels: question
#291 - Error occurs when calibrate IMU and camera with recover covariance
Issue -
State: open - Opened by chengfzy over 5 years ago
- 7 comments
Labels: bug
#291 - Error occurs when calibrate IMU and camera with recover covariance
Issue -
State: open - Opened by chengfzy over 5 years ago
- 7 comments
Labels: bug
#288 - Did not coverge in maxIterations - Multicam Calibration
Issue -
State: closed - Opened by arjunds over 5 years ago
- 3 comments
#288 - Did not coverge in maxIterations - Multicam Calibration
Issue -
State: closed - Opened by arjunds over 5 years ago
- 3 comments
#231 - Multiple (fisheye) camera calibration more fragile with bigger calibration dataset size?
Issue -
State: open - Opened by skohlbr about 6 years ago
- 12 comments
Labels: debugging
#169 - Error when running kalibr_calibrate_rs_cameras
Issue -
State: closed - Opened by TheBigEyedChink over 6 years ago
- 3 comments
Labels: debugging