#38 - Control processor can mix up remote unit command results waiting in serial buffer
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: bug, reliability
#37 - Read sensor value asynchronously
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
- 1 comment
Labels: reliability
#36 - Detect disconnected solenoid
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: enhancement, reliability
#35 - Remote unit voltage converter issue with COMP capacitor
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: bug, hardware
#34 - Controller events are sometimes missed on MQTT
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
- 1 comment
Labels: bug, reliability
#33 - Don't configure RF module when no zones configured
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
Labels: enhancement
#32 - Proper handling of remote unit error responses
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability
#31 - Verifying property updates in the cloud
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability
#30 - Testing with simulated remote units
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: internal, reliability
#29 - Improve controller unit responsiveness with multitasking
Issue -
State: open - Opened by danielmcmillan about 1 year ago
- 1 comment
Labels: enhancement, internal
#28 - When writing invalid config, control unit keeps restarting until hard reboot
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
- 1 comment
Labels: bug
#27 - When sending invalid MQTT topic, it gets stuck in infinite loop
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
Labels: bug, reliability
#26 - After configuring control unit, remote unit update may not be scheduled immediately
Issue -
State: closed - Opened by danielmcmillan about 1 year ago
- 1 comment
Labels: bug, reliability
#25 - Investigate control processor Modbus communication issues
Issue -
State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability
#24 - Support sensor at remote unit with RS485 interface
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
Labels: enhancement
#23 - Updated remote unit hardware
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 3 comments
Labels: hardware
#22 - Better handling of timing out remote unit
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability
#21 - When desired value changes twice in same batch of events, UI is stuck showing spinner
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: bug, reliability
#20 - Authentication
Issue -
State: open - Opened by danielmcmillan over 1 year ago
#19 - Send remote unit available change event after every contact
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
Labels: reliability
#18 - Some active solenoids have repeated on status events
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 1 comment
Labels: bug
#17 - Config validation
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: internal
#16 - Improve remote unit update and retry scheduling
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 2 comments
Labels: reliability
#15 - When updating config, if motor relay is on it gets turned off
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: bug
#14 - Scheduling
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement
#13 - Alert notifications
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability
#12 - Monitoring status in cloud
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement
#11 - Support config to disable Vacon Fieldbus monitoring
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 1 comment
Labels: enhancement
#10 - Indicate controller unit status with LED
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 1 comment
Labels: enhancement
#9 - Refactoring after controllers consolidation
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: internal
#8 - Invalid controller command for remote unit causes controller crash
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
Labels: bug, reliability
#7 - Controller commands interface is unreliable
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 2 comments
Labels: bug
#6 - Updated controller unit hardware
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 2 comments
Labels: hardware
#5 - More reliable and usable UI
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability, UI
#4 - Remote unit configuration UI
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, UI
#3 - Update control processor design documents
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: documentation
#2 - Buffer overflow in event history data structure
Issue -
State: closed - Opened by danielmcmillan over 1 year ago
- 3 comments
Labels: bug, reliability
#1 - Visibility of historical values
Issue -
State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement