Ecosyste.ms: Issues

An open API service for providing issue and pull request metadata for open source projects.

GitHub / danielmcmillan/irrigation-system issues and pull requests

#38 - Control processor can mix up remote unit command results waiting in serial buffer

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: bug, reliability

#37 - Read sensor value asynchronously

Issue - State: closed - Opened by danielmcmillan about 1 year ago - 1 comment
Labels: reliability

#36 - Detect disconnected solenoid

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: enhancement, reliability

#35 - Remote unit voltage converter issue with COMP capacitor

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: bug, hardware

#34 - Controller events are sometimes missed on MQTT

Issue - State: closed - Opened by danielmcmillan about 1 year ago - 1 comment
Labels: bug, reliability

#33 - Don't configure RF module when no zones configured

Issue - State: closed - Opened by danielmcmillan about 1 year ago
Labels: enhancement

#32 - Proper handling of remote unit error responses

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability

#31 - Verifying property updates in the cloud

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability

#30 - Testing with simulated remote units

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: internal, reliability

#29 - Improve controller unit responsiveness with multitasking

Issue - State: open - Opened by danielmcmillan about 1 year ago - 1 comment
Labels: enhancement, internal

#28 - When writing invalid config, control unit keeps restarting until hard reboot

Issue - State: closed - Opened by danielmcmillan about 1 year ago - 1 comment
Labels: bug

#27 - When sending invalid MQTT topic, it gets stuck in infinite loop

Issue - State: closed - Opened by danielmcmillan about 1 year ago
Labels: bug, reliability

#26 - After configuring control unit, remote unit update may not be scheduled immediately

Issue - State: closed - Opened by danielmcmillan about 1 year ago - 1 comment
Labels: bug, reliability

#25 - Investigate control processor Modbus communication issues

Issue - State: open - Opened by danielmcmillan about 1 year ago
Labels: reliability

#24 - Support sensor at remote unit with RS485 interface

Issue - State: closed - Opened by danielmcmillan over 1 year ago
Labels: enhancement

#23 - Updated remote unit hardware

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 3 comments
Labels: hardware

#22 - Better handling of timing out remote unit

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability

#21 - When desired value changes twice in same batch of events, UI is stuck showing spinner

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: bug, reliability

#20 - Authentication

Issue - State: open - Opened by danielmcmillan over 1 year ago

#19 - Send remote unit available change event after every contact

Issue - State: closed - Opened by danielmcmillan over 1 year ago
Labels: reliability

#18 - Some active solenoids have repeated on status events

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 1 comment
Labels: bug

#17 - Config validation

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: internal

#16 - Improve remote unit update and retry scheduling

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 2 comments
Labels: reliability

#15 - When updating config, if motor relay is on it gets turned off

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: bug

#14 - Scheduling

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement

#13 - Alert notifications

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability

#12 - Monitoring status in cloud

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement

#11 - Support config to disable Vacon Fieldbus monitoring

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 1 comment
Labels: enhancement

#10 - Indicate controller unit status with LED

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 1 comment
Labels: enhancement

#9 - Refactoring after controllers consolidation

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: internal

#8 - Invalid controller command for remote unit causes controller crash

Issue - State: closed - Opened by danielmcmillan over 1 year ago
Labels: bug, reliability

#7 - Controller commands interface is unreliable

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 2 comments
Labels: bug

#6 - Updated controller unit hardware

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 2 comments
Labels: hardware

#5 - More reliable and usable UI

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, reliability, UI

#4 - Remote unit configuration UI

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement, UI

#3 - Update control processor design documents

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: documentation

#2 - Buffer overflow in event history data structure

Issue - State: closed - Opened by danielmcmillan over 1 year ago - 3 comments
Labels: bug, reliability

#1 - Visibility of historical values

Issue - State: open - Opened by danielmcmillan over 1 year ago
Labels: enhancement